Characterization of tracking performance for a three-phase reference signal generator for utility connected applications

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Hoyo, J. ; Grad. Studies & Res. Div., Av. Tecnol. S/N, Hermosillo ; Calleja, H. ; Alcala, J.

Grid connected applications require the use of sinusoidal reference signals having low distortion and good frequency tracking performance. This paper presents a reference signal generator for use in three phase power electronics application where grid tracking must be provided. The proposed generator drift from the traditional DQ generator and is a hardware solution. The implementation is intended to be able of release digital control systems from the task of calculating the reference signals. Many control stages of three phase power electronics systems rely on DQ transformation operations to generate the low distorted reference signals. The major drawback of these transformations becomes clear when the grid is unbalanced or there is a frequency drift. A comparison between a DQ generator and the proposed scheme is presented; the testing conditions are severe sag ranging form 50% to 100% of nominal utility value, and frequency variations of around the nominal frequency value. The proposed scheme shows THD levels below 2% in every case simulated, a much lower value than the ones obtained with the classical approach. Experimental values are above 2%, but still below the maximum values of the DQ generator.

Published in:

Power Electronics Congress, 2008. CIEP 2008. 11th IEEE International

Date of Conference: