4 Author(s)
Penman, J. ; University of Aberdeen, Department of Engineering, Aberdeen, UK ; Dey, M.N. ; Tait, A.J. ; Bryan, W.E.

This paper outlines an approach to the monitoring of electrical drives by the method of axial flux sensing. It is shown that it is possible to detect a variety of faults using a single noninvasive sensor. A prototype system design incorporating several novel features is also discussed, and experimental results presented.

Published in:

Electric Power Applications, IEE Proceedings B  (Volume:133 ,  Issue: 3 )