By Topic

Response of saturated-reactor compensators in system-fault operating conditions

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $31
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Hayes, R. ; State Energy Commission of Western Australia, Perth, Australia ; Humpage, W.D. ; Choi, S.S. ; Tunnicliffe, A.
more authors

The findings of recent research reported in the paper relate to some of the properties of reactive-power compensators based on saturated reactors when forced by external faults into momentary operating modes which have a high degree of unbalance between the separate phases. Pronounced unbalance impairs the effectiveness of harmonic cancellation measures internal to reactor systems. In fault operating periods, harmonics are much greater than those in all normal operation in the steady-state. Using a very detailed representation of the multilimb structures of the main-and auxiliary-core systems of saturated reactors in a z-plane electromagnetic transient formulation, harmonic levels are evaluated in the paper for a range of fault operating conditions. The principal factors on which harmonic levels most directly depend are examined including those of fault level, fault type, fault location and the prefault loading conditions in saturated reactors. Comparisons between recordings from livesystem tests and solutions from computer simulation verify the closeness with which the analysis and evaluation facilities used can reproduce system-fault operating conditions. From the basis which harmonic evaluations can provide, the transient loading of harmonic filters in fault operating periods is investigated together with the requirements for protection to which this leads. A study is developed of the co-ordination of filter protection with other protection functions in a complete system which includes reactive-power compensators based on saturated reactors.

Published in:

Generation, Transmission and Distribution, IEE Proceedings C  (Volume:134 ,  Issue: 6 )