Predictive current control of grid-connected neutral-point-clamped converters to meet low voltage ride-through requirements

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

6 Author(s)
Alepuz, S. ; Dept. Electron. Eng., Tech. Univ. of Catalonia, Barcelona ; Busquets-Monge, S. ; Bordonau, J. ; Cortes, P.
more authors

Due to the increase of the distributed power generation in recent years, power system operators have updated their grid connection requirements, in order to include distributed power generation plants operation in the transient operation control of the overall electric power system. Among them, low voltage ride-through requirements demand wind power plant to remain connected to the network in presence of grid voltage dips, contributing to keep network voltage and frequency stable. Wind power technology points to increase voltage levels. Hence, multilevel converters are well suited for this application. The use of symmetrical components to control grid-connected voltage-source converters is simple and effective, but a sequence separation method is needed, which delivers inexact response during a lapse of time after a fault appearance or clearance. This inaccurate response can be a significant drawback. Predictive current control presents similar dynamic response and reference tracking than other well established control methods, but working at lower switching frequencies. In this work, predictive current control is applied to the grid-side NPC converter, in order to fulfil LVRT requirements. Then, a sequence separation method is not needed and inaccuracies after grid fault appearance and clearance are removed from the system performance. DC-link neutral point balance is also achieved by means of the predictive control algorithm, which considers the redundant switching states of the NPC. Simulation results confirm the validity of the proposed control approach.

Published in:

Power Electronics Specialists Conference, 2008. PESC 2008. IEEE

Date of Conference:

15-19 June 2008

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.