By Topic

Low-temperature two-phase micro-channel cooling for high-heat-flux thermal management of defense electronics

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Jaeseon Lee ; Boiling & Two-Phase Flow Lab. (BTPFL), Purdue Univ. Int. Electron. Cooling Alliance (PUIECA), West Lafayette, IN ; Mudawar, I.

For a given heat sink thermal resistance and ambient temperature, the temperature of an electronic device rises fairly linearly with increasing device heat flux. This relationship is especially problematic for defense electronics, where heat dissipation is projected to exceed 1000 W/cm2 in the near future. Direct and indirect low temperature refrigeration cooling facilitate appreciable reduction in the temperature of both coolant and device. This study explores the benefits of cooling the device using direct and indirect refrigeration cooling systems. In the direct cooling system, a micro-channel heat sink serves as an evaporator in a conventional vapor compression cycle using R134a as working fluid. In the indirect cooling system, HFE 7100 is used to cool the heat sink in a primary pumped liquid loop that rejects heat to a secondary refrigeration loop. Two drastically different flow behaviors are observed in these systems. Because of compressor performance constraints, mostly high void fraction two-phase patterns are encountered in the R134a system, dominated by saturated boiling. On the other hand, the indirect refrigeration cooling system facilitates highly subcooled boiling inside the heat sink. Both systems are shown to provide important cooling benefits, but the indirect cooling system is far more effective at dissipating high heat fluxes. Tests with this system yielded cooling heat fluxes as high as 840 W/cm2 without incurring critical heat flux (CHF). Results from both systems are combined to construct an overall map of performance trends relative to mass velocity, subcooling, pressure, and surface tension. Extreme conditions of near-saturated flow, low mass velocity, and low pressure produce 'micro' behavior, where macro-channel flow pattern maps simply fail to apply, instabilities are prominent, and CHF is quite low. One the other hand, systems with high mass velocity, high subcooling, and high pressure are far more stable and yield- very high CHF values; two-phase flow in these systems follows the fluid flow and heat transfer behavior as well as the flow pattern maps of macro-channels.

Published in:

Thermal and Thermomechanical Phenomena in Electronic Systems, 2008. ITHERM 2008. 11th Intersociety Conference on

Date of Conference:

28-31 May 2008