Comparative assessment of different energy mapping methods for generation of 511-keV attenuation map from CT images in PET/CT systems: A phantom study

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Shirmohammad, M. ; Dept. of Med. Phys. & Biomed. Eng., Univ. of Tehran, Tehran ; Ay, M.R. ; Sarkar, S. ; Ghadiri, H.
more authors

The use of X-ray CT images for CT-based attenuation correction (CTAC) of PET data results in the decrease of overall scanning time and creates a noise-free attenuation map (mumap). The linear attenuation coefficient (LAC) measured with CT is calculated at the x-ray energy rather than at the 511 keV. It is therefore necessary to convert the linear attenuation coefficients obtained from the CT scan to those corresponding to the 511 keV. Several conversion strategies have been developed including scaling, segmentation, hybrid, bilinear and dual-energy decomposition methods. The aim of this study is to compare the accuracy of different energy mapping methods for generation of attenuation map form CT images. An in-house made polyethylene phantom with different concentrations of K2HPO4 was used in order to quantitatively measure the accuracy of the nominated methods, using quantitative analysis of created mumaps. The generated mumaps using different methods compared with theoretical values calculated using XCOM cross section library. Accurate quantitative analysis showed that for low concentrations of K2HPO4 all these methods produce acceptable attenuation maps at 511 keV, but for high concentration of K2HPO4 the last three methods produced the lowest errors (10.1% in hybrid, 9.8% in bilinear, and 4.7% in dual energy method). The results also showed that in dual energy method, combination of 80 and 140 kVps produces the least error (4.2%) compared to other combinations of kVps.

Published in:

Biomedical Imaging: From Nano to Macro, 2008. ISBI 2008. 5th IEEE International Symposium on

Date of Conference:

14-17 May 2008