Close category search window
 

Three-Dimensional Ventricular Activation Imaging by Means of Equivalent Current Source Modeling and Estimation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Liu, Z. ; Dept. of Biomed. Eng., Minnesota Univ., Minneapolis, MN ; Liu, C. ; He, B.

This paper presents a novel electrocardiographic inverse approach for imaging the 3-D ventricular activation sequence based on the modeling and estimation of the equivalent current density throughout the entire myocardial volume. The spatio-temporal coherence of the ventricular excitation process is utilized to derive the activation time from the estimated time course of the equivalent current density. At each time instant during the period of ventricular activation, the distributed equivalent current density is noninvasively estimated from body surface potential maps (BSPM) using a weighted minimum norm approach with a spatio-temporal regularization strategy based on the singular value decomposition of the BSPMs. The activation time at any given location within the ventricular myocardium is determined as the time point with the maximum local current density estimate. Computer simulation has been performed to evaluate the capability of this approach to image the 3-D ventricular activation sequence initiated from a single pacing site in a physiologically realistic cellular automaton heart model. The simulation results demonstrate that the simulated "true" activation sequence can be accurately reconstructed with an average correlation coefficient of 0.90, relative error of 0.19, and the origin of ventricular excitation can be localized with an average localization error of 5.5 mm for 12 different pacing sites distributed throughout the ventricles

Published in:
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE

Date of Conference: Aug. 30 2006-Sept. 3 2006

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.