By Topic

A High-Frame Rate Duplex Ultrasound Biomicroscopy for Small Animal Imaging In vivo

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

6 Author(s)
Lei Sun ; Dept. of Health Technol. & Inf., Hong Kong Polytech. Univ., Kowloon ; Xiaochen Xu ; Richard, W.D. ; Ching Feng
more authors

Much of the current knowledge of human cardiovascular pathologies and treatment strategies has been gained from understanding the cardiac physiologies and functions in small animal models, such as mice, rats, and zebraflsh. In this paper, we present the development of a high-frame-rate duplex ultrasound biomicroscopy (UBM) capable of B-mode imaging and pulsed-wave (PW) Doppler measurement for in vivo cardiovascular investigation in small animals. A frame rate of 200 frames per second (fps) was accomplished at a view of 5 mm times 8 mm, using a novel highspeed sector probe and specially designed lightweight transducers. In a reduced lateral view of 1.2 mm, a frame rate of 400 fps was achieved to examine more detailed cardiac motion. The UBM utilized transducers with different center frequencies (40-75 MHz) and geometries, which made it useful for various applications in small animal cardiac imaging. The highest spatial resolution the UBM achieved was 25 mum times 56 mum. In addition, the image-guided PW Doppler implemented in the UBM demonstrated the detection of the velocity of a moving wire as low as 0.1 mm/s, and flow in a polyimide tube as small as 200 mum in diameter. Furthermore, the UBM achieved a 15-muV minimal detectable signal and a 60-dB dynamic range using a low-cost PCB-based design. Finally, sample in vivo cardiac images of mouse and zebraflsh hearts were given. These results showed that the UBM integrated with B-mode and PW Doppler is useful to investigate the pathophysiological mechanism in the cardiovascular studies.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:55 ,  Issue: 8 )