Imaging characteristics of the direct and mobile indirect digital radiographic systems

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)

The clinical applications of the current digital radiographic (DR) systems are rapidly growing. With the recent advances in electronic and ubiquitous healthcare systems using digital imaging modalities, the interest of researchers in developing a mobile digital-imaging system for teleradiologic applications in remote areas is growing. These authors recently installed a mobile indirect digital radiographic (IDR) system in their laboratory and conducted this study to evaluate its characteristics. The characteristics of the general direct digital radiographic (DDR) system that was also installed in these authors' laboratory were likewise studied to determine the difference between the two systems. The performances of the two DR systems were evaluated by measuring their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). For these measurements, two radiographic systems were used; a DR-1000 (TOSHIBA E7239X generator with a Direct Radiography Corp. DR-1000 detector) and an Alpha-R4000 (LISTEM Mobix-1000 generator with a Teleoptic PRA Alpha-R4000 detector). The imaging characteristics of the two systems were measured using the IEC- 61267-defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The results for the general DDR system, MTF at 10% and DQE values using 1.4 mR at Ocycles/mm were measured as 5.37 cycles/mm and 24%, respectively. The NPS curves were almost constant at the wide range of the spatial frequencies. For the mobile IDR system, MTF at 10% and DQE values using 1.3 mR at Ocycles/mm were measured as 2.4 cycles/mm and 10%, respectively. The NPS curves gradually decreased at frequencies above 0.25 cycles/mm. The DQE of the general DDR system linearly decreased as a function of the spatial frequencies, but that of the mobile IDR system exponentially decreased. The DQEs of the two systems differed significantly at different radiation doses. The results suggested that the actual teleradiol- ogic imaging applications of the mobile IDR system requires further studies in real situations.

Published in:

Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE  (Volume:5 )

Date of Conference:

Oct. 26 2007-Nov. 3 2007