10B-1 Strain Imaging of Arterial Wall with Translational Motion Compensation and Error Correction

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Hasegawa, H. ; Tohoku Univ., Sendai ; Kanai, H.

To assess elastic properties, correlation techniques are widely used to measure the displacement and strain of the arterial wall caused by the heartbeat. However, the displacements estimated by the phase-sensitive correlation methods are biased when the frequency used for the displacement estimation is different from the center frequency of RF echo. One of reasons for the frequency variation is the interference of echoes. In the case of the arterial wall, the displacement due to radial translation is larger than that contributing to strain by a factor of 10 and, thus, the error resulting from the translational motion due to the mismatch between the frequency used for displacement estimation and the actual center frequency is not negligible compared with the minute displacement contributing to strain. In this study, a method is proposed in which the radial translation is removed prior to the calculation of complex correlation between echoes in two different frames to estimate the phase change between the echoes. The radial translation is removed by tracking the echo from the luminal interface of the wall because it is dominant compared with echoes from scatterers in the wall and is less affected by the interference. Using this procedure, the significant error resulting from the large translation can be greatly suppressed. After the removal of translation, an error correcting function based on complex correlation is introduced to further reduce the error due to the frequency mismatch. Accuracy improvement by the proposed method was validated using phantoms. As shown in the figure, the error in strain estimated by the proposed method was 12.0% from the theoretical strain profile, significantly smaller than that (23.7%) by the conventional method. Furthermore, in the in vitro experiments using extracted femoral arteries, the arterial wall containing calcined tissue showed very small strain in comparison with that almost homogeneously composed of fibrous tissue (mixture - of smooth muscle and collagen). The means and the standard deviations of distensibility (calculated from strain and internal pressure) of fibrous and calcined tissues obtained for 7 sections of 5 femoral arteries were 2.42plusmn2.1 and 0.35plusmn0.50 MPa-1, respectively.

Published in:

Ultrasonics Symposium, 2007. IEEE

Date of Conference:

28-31 Oct. 2007