ESD failures can occur in ESD protected areas that are designed according to the latest ESD standards like ANSI S20.20 or IEC 61340-5-1. The root cause for the failures can normally only be found by a detailed analysis of the whole production flow. This paper shows what hazards for ESD damages can occur in a typical process flow of a typical PCB manufacturing line, how the risk is going to be analyzed, and how it can be minimized. This method will be explained with some examples from the field.

Published in:

29th Electrical Overstress/Electrostatic Discharge Symposium, 2007. EOS/ESD

Date of Conference:

16-21 Sept. 2007