Cart (Loading....) | Create Account
Close category search window
 

Performance Study of Single-Slice Positron Emission Tomography Scanners by Monte Carlo Techniques

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)

A Monte Carlo simulation of the gamma ray transport within a single-slice positron emission tomograph has been generated to study the effects of system parameters on performance. Included in the simulation are the radioactive source distribution, collimators, and detectors with intercrystal septa. Data are first presented to show the coincidence and singles sensitivities as a function of ring radius. Then, for a fixed radius of 26 cm, the variation of sensitivities are shown as a function of the following variables: slice thickness, patient port size, intercrystal septum dimensions, lower energy discriminator level, and coincidence fan angle. Simulation-generated sensitivity data are compared with experimental values for several tomographs andgood agreement is obtained. Discrepancies between two definitions used in experimentally determining scatter fractions are discussed. The Monte Carlo simulation shows that small radii rings have an effective count rate (quality factor) that is more than 90 percent of that for larger rings at low and moderate activity levels (?? 0.25 ??Ci??cm-3), contrary to what is predicted from analytical calculations. It is concluded that small radius rings are better suited for low dose-rate static studies, while larger radius rings are preferred for high dose-rate dynamic studies.

Published in:

Medical Imaging, IEEE Transactions on  (Volume:2 ,  Issue: 4 )

Date of Publication:

Dec. 1983

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.