Cart (Loading....) | Create Account
Close category search window
 

A Dual-Functional Medium Voltage Level DVR to Limit Downstream Fault Currents

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Yun Wei Li ; Nanyang Technol. Univ., Singapore ; Vilathgamuwa, D.M. ; Poh Chiang Loh ; Blaabjerg, F.

The dynamic voltage restorer (DVR) is a modern custom power device used in power distribution networks to protect consumers from sudden sags (and swells) in grid voltage. Implemented at medium voltage level, the DVR can be used to protect a group of medium voltage or low voltage consumers. However, the DVR will therefore be tasked to mitigate even more faults involving downstream loads. Large fault currents would flow through the DVR during a downstream fault before the opening of a circuit breaker. This will cause the voltage at point of common coupling (PCC) to drop, which would affect the loads on the other parallel feeders connected to PCC. Furthermore, if not controlled properly, the DVR might also contribute to this PCC voltage sag in the process of compensating the missing voltage, thus further worsening the fault situation. To limit the flow of large line currents, and therefore restore the PCC voltage as well as protect the DVR system components, a downstream fault limiting function is proposed and integrated in the DVR operation. A flux-charge-model feedback algorithm is implemented so that the DVR would act as a large virtual inductance in series with the distribution feeder in fault situations. Controlling the DVR as a virtual inductor would also ensure zero real power absorption during the DVR compensation and thus minimize the stress in the dc link. Finally, the proposed fault current limiting algorithm has been tested in Matlab/Simulink simulation and experimentally on a medium voltage level laboratory DVR system.

Published in:

Power Electronics, IEEE Transactions on  (Volume:22 ,  Issue: 4 )

Date of Publication:

July 2007

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.