Scheduled System Maintenance:
On May 6th, single article purchases and IEEE account management will be unavailable from 8:00 AM - 12:00 PM ET (12:00 - 16:00 UTC). We apologize for the inconvenience.
By Topic

Urethral Sphincter EMG as Event Detector for Neurogenic Detrusor Overactivity

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

6 Author(s)

The aim of this study was to investigate the feasibility of using external urethral sphincter electromyogram (EMG) (EUSEMG) to detect the onset of detrusor contractions in patients with both neurogenic detrusor overactivity (NDO) and detrusor sphincter dyssynergia (DSD). Detrusor pressure (Pdet) and EUSEMG was recorded in 23 neurogenic patients during slow artificial bladder filling. The time delay between the onset of EUSEMG detrusor contraction and the onset of activity was calculated together with the detrusor pressure increase related to this delay. Of 23 patients enrolled, 12 patients showed both NDO and DSD. Of these 12 patients, 10 had a strong correlation between detrusor pressure and EUSEMG . One patient in this group was excluded due to a storage pressure above 30 cmH2O . Two detection methods were applied on the remaining 9 patients. Method 1 was a root mean square (RMS)-integrator with simple thresholding. This approach had a good sensitivity but also a poor specificity (many false-positive detections). Detection method 2 included a kurtosis-based scaling function, which was multiplied to a similar RMS-integrator as used in method 1. Onset detection occurred before Pdet exceeded 18 cmH2O with both methods. However, method 1 resulted in 14.1plusmn12.8 false-positive detections during one bladder filling.Pdet at onset detection was on average 1.0plusmn1.1 cmH2O higher with detection method 2 but the number of false-positives was reduced by 95.8%. This paper demonstrates the feasibility of using EUSEMG to estimate the onset of a detrusor contraction in selected patients.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:54 ,  Issue: 7 )