Geometrical Repeatability and Motion Blur Analysis of a New Multi-projection X-ray Imaging System

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Chawla, A.S. ; Duke Adv. Imaging Labs., Duke Univ., Durham, NC ; Samei, E.

We report on the reproducibility and tests for possible motion blur artifacts of a new high frame-rate prototype X-ray multi-projection system recently installed in the Radiology Department of Duke University. The system, which has a translating X-ray tube but a stationary detector, is capable of acquiring oblique-angled full field projection images along both the vertical and horizontal axes at variable speeds and acquisition frame rates. The angular span of the tube movement is +7.5deg to -7.5deg about the posterior-anterior (PA) orientation. To analyze the effect of possible blurring artifact due to motion of the X-ray tube, multi-angled projection images of an edge device were acquired. The modulation transfer function (MTF) determined from the PA projection acquired with and without the tube in motion was compared to investigate blur artifacts that may be introduced due to motion of the X-ray tube. Geometrical precision of the system was assessed at two tube speeds by evaluating the recorded position coordinates as well as edge positions in repeated acquisitions. Excellent geometrical consistency was found in the tube motion. The positional errors at tube speeds of 1 and 2 in/sec were found to be within 1%. The possible effect on the MTF due to motion of the tube was found to be inconsequential. The system was deemed ready for actual clinical trials with these acquisition parameters.

Published in:

Nuclear Science Symposium Conference Record, 2006. IEEE  (Volume:5 )

Date of Conference:

Oct. 29 2006-Nov. 1 2006

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.