14 Author(s)
Scribner, D. ; Opt. Sci. Div., Naval Res. Lab., Washington, DC ; Johnson, L. ; Skeath, Perry ; Klein, R.
more authors

A very large format neural stimulator device, to be used in future retinal prosthesis experiments, has been designed, fabricated, and tested. The device was designed to be positioned against a human retina for short periods in an operating room environment. Demonstrating a very large format, parallel interface between a 2-D microelectronic stimulator array and neural tissue would be an important step in proving the feasibility of high resolution retinal prosthesis for the blind. The architecture of the test device combines several novel components, including microwire glass, a microelectronic multiplexer, and a microcable connector. The array format is 80 times 40 array pixels with approximately 20 microwire electrodes per pixel. The custom assembly techniques involve indium bump bonding, ribbon bonding, and encapsulation. The design, fabrication, and testing of the device has resolved several important issues regarding the feasibility of high-resolution retinal prosthesis, namely, that the combination of conventional CMOS electronics and microwire glass provides a viable approach for a high resolution retinal prosthesis device. Temperature change from power dissipation within the device and maximum electrical output current levels suggest that the device is acceptable for acute human tests

Published in:
Biomedical Circuits and Systems, IEEE Transactions on  (Volume:1 ,  Issue: 1 )

Date of Publication: March 2007

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.