Endothelial Cell Electrical Impedance Parameter Artifacts Produced by a Gold Electrode and Phase Sensitive Detection

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
English, A.E. ; Tennessee Univ., Knoxville, TN ; Squire, J.C. ; Bodmer, J.E. ; Moy, A.B.

Frequency dependent cellular micro-impedance estimates obtained from a gold two-electrode configuration using phase sensitive detection have become increasingly used to evaluate cellular barrier model parameters. The results of this study show that cellular barrier function parameter estimates optimized using measurements obtained from this biosensor are highly susceptible to both time dependent and systematic instrumental artifacts. Based on a power spectral analysis of experimentally measured microelectrode voltages, synchronous, 60 Hz, and white Gaussian noise were identified as the most significant time dependent instrumental artifacts. The reduction of these artifacts using digital filtering produced a corresponding reduction in the optimized model parameter fluctuations. Using a series of instrumental circuit models, this study also shows that electrode impedance voltage divider effects and circuit capacitances can produce systematic deviations in cellular barrier function parameter estimates. Although the implementation of an active current source reduced the voltage divider effects, artifacts produced by coaxial cable and other circuit capacitive elements at frequencies exceeding 1 kHz still remained. Reducing time dependent instrumental fluctuations and systematic errors produced a significant reduction in cellular model barrier parameter errors and improved the model fit to experimental data

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:54 ,  Issue: 5 )

Date of Publication:

May 2007

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.