Cart (Loading....) | Create Account
Close category search window
 

Magnetic Induction Heating of Ferromagnetic Implants for Inducing Localized Hyperthermia in Deep-Seated Tumors

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Stauffer, P.R. ; Department of Radiation Oncology, University of California ; Cetas, Thomas C. ; Jones, Roger C.

A variable frequency magnetic induction heating system has been developed for localized hyperthermic treatment of deep-seated tumors via power deposition into arrays of 1-2 mm diameter ferromagnetic cylindrical implants. The frequency dependence of implant heating compared to that induced directly into tissues indicates use of frequencies below 4 MHz. Above 10 MHz, tissues are heated directly from the induced eddy currents. Thermographic analyses of temperature distributions induced in tissues equivalent phantom models and in exposed animal tissues in vivo have been performed for several implant materials and array configurations. Results of the thermal dosimetry show that the majority of tissue contained within multiimplant arrays can be heated such that the temperature rises to 55-70 percent of the implant temperature differential. The resulting tissue temperature distribution is dependent on local blood flow and array characteristics, but not significantly on tissue electrical properties. Operating the system at 1.9. MHz, we demonstrate that it is possible to raise an implanted volume to therapeutic temperatures safely, in less than 10 min, with little increase in temperature outside the array boundaries.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:BME-31 ,  Issue: 2 )

Date of Publication:

Feb. 1984

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.