Validity conditions for complete and partial local thermodynamic equilibrium (CLTE and PLTE) of homogeneous, time-dependent, and optically thin plasmas are derived. For Cu I, electron densities of ne⩾(5×1022-5×1023 ) m-3 are required for the establishment of CLTE. For Cu I and Cu II, ne⩾(5×1021-5×1021 -5×1022) m-3 is necessary for PLTE (for electron temperatures of 1-2 eV). Application to low-current copper vapor arcs in vacuum shows that CLTE can be expected for r<200-600 μm (r=distance from the cathode spot). A further limitation follows for temperatures of 2 eV or higher if diffusion effects are taken into consideration. Consequently, the use of the LTE formulas in plasma spectroscopy of low-current vacuum arcs is very limited
Published in:
Plasma Science, IEEE Transactions on
(Volume:17
,
Issue:
5
)
Date of Publication:
Oct 1989
- Page(s):
-
653
-
656
- ISSN :
-
0093-3813
- INSPEC Accession Number:
-
3561858
- Digital Object Identifier :
-
10.1109/27.41175
- Product Type:
-
Journals & Magazines
- Date of Current Version :
-
06 August 2002
- Issue Date :
-
Oct 1989
- Sponsored by :
-
IEEE Nuclear and Plasma Sciences Society