Shi-Qing Wang ; OnWafer Technol., Inc., Pleasanton, CA ; MacDonald, P. ; Kruger, M.

Plasma etch in semiconductor chip manufacturing is a complex process. The final process performance depends strongly on process parameters and their distributions at the surface of production wafers in an etch chamber. Until recently, there was no known technique that could monitor such critical parameters in-situ at the wafer surface before. In this paper the authors discuss an innovative technology where novel wireless sensor wafers (PlasmaTemptrade) are combined with advanced chamber diagnostic modeling techniques (PlasmaRxtrade) to provide a powerful solution-focused system for in-situ etch chamber component health monitoring, questionable component identification, and further corrective action

Published in:

Solid-State and Integrated Circuit Technology, 2006. ICSICT '06. 8th International Conference on

Date of Conference:

23-26 Oct. 2006