Study of Grid-Side Converter Control for Grid-Connected DFIG Wind Turbines under Unbalanced Load Condition

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

The purchase and pricing options are temporarily unavailable. Please try again later.
4 Author(s)
Tremblay, E. ; Departement de Genie Electrique, Quebec Univ., Montreal, Que. ; Chandra, A. ; Lagace, P.J. ; Gagnon, R.

A doubly fed induction generator wind turbine (DFIG-WT) under unbalanced load condition is presented. It is demonstrated that the grid-side converter can supports the grid under unbalanced load conditions as well as provide power factor correction without disturbing the DFIG-WT. The controller is based on symmetrical components and a vector control scheme. With the grid-side converter, power compensation support can be done at a specific point away from the wind turbine plant. The system is fully operational at zero output power from the DFIG-WT and independent of the rotor-side control strategy. Simulation results illustrate good performance of the proposed system

Published in:

Industrial Electronics, 2006 IEEE International Symposium on  (Volume:2 )

Date of Conference:

9-13 July 2006