Cart (Loading....) | Create Account
Close category search window
 

The Effects of Flow Dispersion and Cardiac Pulsation in Arterial Spin Labeling

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Wen-Chau Wu ; California Univ., San Diego, La Jolla, CA ; Mazaheri, Y. ; Wong, E.C.

The blood in the carotid arteries exhibits time-varying flow velocity as a function of cardiac phases. Despite this flow velocity variation, most current methods set forth for the analysis of arterial spin labeling (ASL) data have assumed that the tagged blood is delivered from the tagging region to the imaging region via simple plug flow, i.e., a single transit delay (deltat). In this study, we used a pulse oximeter to synchronize image acquisition at systole and diastole separately. The deltat dispersion was modeled with a Gaussian distribution and the effect of cardiac pulsation upon the ASL signal was evaluated on five healthy volunteers. ASL signals were collected at a series of inflow times (TI) using PICORE QUIPSS II: TR/TE/TI1=2400/3.2/700 ms, TI={300,500,700,900,1100,1300,1500} ms, matrix size=64times64,repetition=100. Transit delay was found significantly shorter in systolic tag than diastolic tag (paired student's t-test, p<0.001; mean difference across subjects=54 ms). When the tag was applied in late systole, the ASL signal arrived in the target brain slice earlier, and was higher by 16% with TI=700 ms. Intervoxel dispersion (~350 ms) dominated over intravoxel dispersion (<200 ms). The disparity of ASL signals found between systolic and diastolic tags indicated that ASL imaging was sensitive to cardiac pulsations. We conclude that both flow dispersion and fluctuations in the ASL signal due to cardiac pulsations are significant

Published in:

Medical Imaging, IEEE Transactions on  (Volume:26 ,  Issue: 1 )

Date of Publication:

Jan. 2007

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.