The transient response of lossy coupled transmission lines is simulated by iterative waveform relaxation analyses of equivalent disjoint networks constructed with congruence transformers, fast-Fourier-transform waveform generators, and characteristic impedances synthesized by the Pade approximation. A two-order reduction of central-processing-unit time and a one-order savings in computer memory have been achieved. A lossy directional coupler is simulated for illustration.<>

Published in:

Microwave Symposium Digest, 1989., IEEE MTT-S International

Date of Conference:

13-15 June 1989