Close category search window
 

Computational studies of transthoracic and transvenous defibrillation in a detailed 3-D human thorax model

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Jorgenson, D.S. ; Heartstream Inc., Seattle, WA, USA ; Haynor, D.R. ; Bardy, G.H. ; Yongmin Kim

A method for constructing and solving detailed patient-specific 3D finite element models of the human thorax is presented for use in defibrillation studies. The method utilizes the patient's own X-ray CT scan and a simplified meshing scheme to quickly and efficiently generate a model typically composed of approximately 400,000 elements. A parameter sensitivity study on one human thorax model to examine the effects of variation in assigned tissue resistivity values, level of anatomical detail included in the model, and number of CT slices used to produce the model is presented. Of the seven tissue types examined, the average left ventricular (LV) myocardial voltage gradient was most sensitive to the values of myocardial and blood resistivity. Incorrectly simplifying the model, for example modeling the heart as a homogeneous structure by ignoring the blood in the chambers, caused the average LV myocardial voltage gradient to increase by 12%. The sensitivity of the model to variations in electrode size and position was also examined. Small changes (<2.0 cm) in electrode position caused average LV myocardial voltage gradient values to increase by up to 12%. It is concluded that patient-specific 3D finite element modeling of human thoracic electric fields is feasible and may reduce the empiric approach to insertion of implantable defibrillators and improve transthoracic defibrillation techniques.

Published in:
Biomedical Engineering, IEEE Transactions on  (Volume:42 ,  Issue: 2 )

Date of Publication: Feb. 1995

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2013 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.