Scheduled System Maintenance on May 29th, 2015:
IEEE Xplore will be upgraded between 11:00 AM and 10:00 PM EDT. During this time there may be intermittent impact on performance. We apologize for any inconvenience.
By Topic

A reconstruction algorithm using singular value decomposition of a discrete representation of the exponential radon transform using natural pixels

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Gullberg, G.T. ; Dept. of Radiol., Utah Univ., Salt Lake City, UT, USA ; Zeng, G.L.

An algorithm to correct for constant attenuation in SPECT is derived from the singular value decomposition (SVD) of a discrete representation of the exponential Radon transform using natural pixels. The algorithm is based on the assumption that a continuous image can be obtained by backprojecting the discrete array q, which is the least squares solution to Mq=p, where p is the array of discrete measurements, and the matrix M represents the composite operator of the backprojection operator A/sub /spl mu//* followed by the projection operator A/sub /spl mu//. A singular value decomposition of M is used to solve the equation Mq=p, and the final image is obtained by sampling the backprojection of the solution q at a discrete array of points. Analytical expressions are given to calculate the matrix elements of M that are integrals of exponential factors over the overlapped area of two projection strip functions (natural pixels). A spectral analysis of the exponential Radon transform is compared with that of the Radon transform. The condition number of the spectrum increases with increased attenuation coefficient, which correlates with the increase in statistical error propagation seen in clinical images obtained with low-energy radionuclides. Computer simulations using 32 projections sampled over 360 degrees show an improvement in the SVD reconstruction over the convolution backprojection reconstruction, especially when the projection data is corrupted with noise.<>