State feedback control of current-type PWM AC-to-DC converters

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

The purchase and pricing options are temporarily unavailable. Please try again later.
2 Author(s)
Sato, Y. ; Dept. of Electr. & Electron. Eng., Tokyo Inst. of Technol., Japan ; Kataoka, T.

A control method for current-type PWM AC-to-DC converters that realizes a sinusoidal AC input current and unity power factor is discussed in detail. In such converters, an LC filter placed on the AC side may cause a resonant problem, especially in the transient condition. To overcome this problem, state feedback control is introduced, and a control strategy suitable for DC-output current control as well as AC-side current control is proposed. Circuit parameters and feedback coefficients in the AC-side current control system are optimized on the basis of an analysis in which the system is treated as a sampled-data system. A method of investigating parameters in the DC-side current control system is shown. To confirm the effectiveness of the control strategy and the validity of the analytical results, an experimental investigation of the basic characteristics of the system is made. As an example, this system is applied to controlling the current waveform in the reactor. The experimental results for this application are also included

Published in:

Industry Applications, IEEE Transactions on  (Volume:29 ,  Issue: 6 )