By Topic

Efficient electrode spacing for examining spatial organization during ventricular fibrillation

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

5 Author(s)
Bayly, P.V. ; Sch. of Eng., Duke Univ., Durham, NC, USA ; Johnson, E.E. ; Idriss, S.F. ; Ideker, R.E.
more authors

Spatial organization has been observed during episodes of ventricular fibrillation (VF) by recording epicardial unipolar electrograms on a grid of electrodes. In such studies, the choice of spacing between electrodes is an important decision, affecting the resolution and the size of the domain to be studied. A basic tenet of sampling theory, the Nyquist criterion, states that an electrode spacing smaller than half the smallest significant wavelength is required to capture the important details of a spatially sampled process. The authors suggest a method to choose a practical interelectrode spacing by examining wavenumber power spectra of high-resolution VF data recorded from a square 11*11 array of electrodes spaced 0.28 mm apart. The plaque was sutured on the epicardium near the left ventricular apex in 7 anesthetized pigs. VF was induced with AC simulation. Unipolar extracellular electrograms were simultaneously recorded from each channel for 2 s after the induction of VF. Each signal was sampled in time at 1000 Hz. Wavenumber power spectra were calculated for 100 ms segments using the zero-delay wavenumber spectrum method, for a total of 140 power spectra. All spectra had dominant peaks at the origin and fell off rapidly with increasing wavenumber (decreasing wavelength). In all the spectra, every wavelength shorter than 1.4 mm contributed insignificant power. Furthermore, in 134 of 140 spectra (96%), insignificant power levels were associated with every wavelength shorter than 2.8 mm. These results suggest that, for unipolar extracellular electrodes, an intersensor spacing on the order of 1 mm is appropriate to study organization during early VF.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:40 ,  Issue: 10 )