V. Bego ; Fac. of Eng., Zagreb Univ., Yugoslavia ; J. Butorac ; G. Gasljevic

A method by which air capacitor electrodes are charged with a DC voltage and then quickly discharged is described. Immediately afterwards, a very sensitive Coulombmeter is switched on to measure the additional discharging of thin dielectric films on the electrodes. The method makes possible the measurement of effects having a time constant of several milliseconds to several thousand seconds, and also enables the frequency dependence of the capacitance to be determined, even for time constants below 1 ms