Cart (Loading....) | Create Account
Close category search window
 

Continuous digital calibration of pipeline A/D converters

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Delic-Ibukic, A. ; Dept. of Electr. & Comput. Eng., Univ. of Maine, Orono, ME ; Hummels, D.M.

This paper describes a novel continuous calibration technique for pipeline analog-to-digital converters (ADCs). The new scheme utilizes an existing digital calibration algorithm and extends it to work in real time. The goal is to digitally calibrate the pipeline ADCs in the background without interrupting the normal operation of the converter. The concept behind the digital calibration algorithm is described and simulated using a 1-bit/stage pipeline architecture. Dominant static error mechanisms present in pipeline architectures are identified and discussed. These errors are successfully corrected by the implemented digital calibration algorithm. The calibration scheme is transparent to the overall system performance and is demonstrated using a 14-bit ADC with a 1-bit/stage architecture and 16 identical stages. The first seven stages in the pipeline are calibrated. Continuous calibration is realized using a hardware description language and two extra stages located at the end of the pipeline. The extra stages are only used during the calibration process. Verilog implementations of a stage-and-error-correction logic, as well as a finite state machine to control the calibration process, are presented. The real-time digital calibration technique is verified and successfully demonstrated using the Verilog-XL simulator

Published in:

Instrumentation and Measurement, IEEE Transactions on  (Volume:55 ,  Issue: 4 )

Date of Publication:

Aug. 2006

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.