Cart (Loading....) | Create Account
Close category search window
 

Current injection for active islanding detection of electronically-interfaced distributed resources

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Hernandez-Gonzalez, G. ; Dept. of Electr. & Comput. Eng., Univ. of Toronto, Ont., Canada ; Iravani, R.

This paper presents an active islanding detection method for electronically-interfaced distributed resource units at the distribution voltage level. The proposed method is based on injecting a disturbance signal into the system through either the direct axis (d-axis) or the quadrature axis (q-axis) current controllers of the interface voltage-sourced converter. Signal injection through the d-axis controller modulates the amplitude of the voltage at the point of common coupling (PCC), whereas signal injection through the q-axis controller causes a frequency deviation at PCC, under islanded conditions. Monitoring strategies to detect islanding are also presented for the proposed injection method. The feasibility of the proposed method is evaluated under the UL1741 anti-islanding test configuration. The studies reported in this paper are based on time-domain simulations in the PSCAD/EMTDC environment. The studies show that the proposed islanding detection method succeeds in detecting the islanding phenomenon as fast as 33.3 ms for the parameter setting of the test system, and always meets the two-second UL detection requirement. The paper also concludes that the proposed method has the salient feature of offering a potential application in a micro-grid scenario, where fast "islanding detection" and not necessarily the "anti-islanding function" is required.

Published in:

Power Delivery, IEEE Transactions on  (Volume:21 ,  Issue: 3 )

Date of Publication:

July 2006

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.