Local noise weighted filtering for emphysema scoring of low-dose CT images

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
A. M. R. Schilham ; Image Sci. Inst., Univ. Med. Center Utrecht, Netherlands ; B. van Ginneken ; H. Gietema ; M. Prokop

Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on intensity, this measure is strongly influenced by noise. This effect shows up clearly when comparing the PI score of a high-dose scan to the PI score of a low-dose (i.e., noisy) scan of the same subject. In this paper, the noise variance (NOVA) filter is presented: a general framework for (iterative) nonlinear filtering, which uses an estimate of the spatially dependent noise variance in an image. The NOVA filter iteratively estimates the local image noise and filters the image. For the specific purpose of emphysema quantification of low-dose CT images, a dedicated, noniterative NOVA filter is constructed by using prior knowledge of the data to obtain a good estimate of the spatially dependent noise in an image. The performance of the NOVA filter is assessed by comparing characteristics of pairs of high-dose and low-dose scans. The compared characteristics are the PI scores for different thresholds and the size distributions of emphysema bullae. After filtering, the PI scores of high-dose and low-dose images agree to within 2%-3%points. The reproducibility of the high-dose bullae size distribution is also strongly improved. NOVA filtering of a CT image of typically 400×512×512 voxels takes only a couple of minutes which makes it suitable for routine use in clinical practice.

Published in:

IEEE Transactions on Medical Imaging  (Volume:25 ,  Issue: 4 )