Cart (Loading....) | Create Account
Close category search window
 

Improved gamma camera performance using event positioning method based on distance dependent weighting

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Vesel, J. ; Philips Med. Syst., Cleveland, OH ; Petrillo, M.

Event positioning algorithms for scintillation gamma cameras are typically based on centroid ("Anger") positioning algorithms that weight photomultiplier tube (PMT) responses by their PMT location. Iterative maximum-likelihood based algorithms use measured PMT responses to provide more accurate position estimates, but suffer from long computational times that limit the use in large field-of-view gamma cameras in real-time systems. An improvement to the centroid-based method is to use an iterative distance dependent weighting method to modify the individually measured PMT responses. The distances from the initial event position estimate to each PMT location is calculated. Each distance is used to index into a weighting table designed to optimize PMT signal-to-noise for better detector resolution, improve the non-linearity of the PMT response in scintillation cameras for more accurate position estimates, and correct for energy dependent mean detector light responses. The Philips EPIC-AZ detector with a single 200 MHz TMS320C6204 DSP has a throughput of 4.3 musec per event for two iterations. Intrinsic spatial resolution has improved by ~0.2 mm to typically 3.1 mm FWHM. Intrinsic integral flood uniformity of <2.5% for Ga-67 can be achieved with a Tc-99 flood correction table by fixing the PMT high voltage and calibrating PMT gain tracking errors

Published in:

Nuclear Science Symposium Conference Record, 2005 IEEE  (Volume:5 )

Date of Conference:

23-29 Oct. 2005

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.