Realistic Monte Carlo PET simulation with pixellated block detectors, light sharing and randoms modeling

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
B. Guerin ; Paris VI Univ., France ; G. El Fakhri

We have developed a realistic Monte Carlo simulation based on the SimSET software to model photon transport and detection in PET scanners using the block design, modeling explicitly random coincidences, pixellated block detectors and light sharing among crystals elements. Our modeling was validated by comparison to a general purpose Monte Carlo transport code that has been extensively validated previously (GATE) as well as comparison to measurements made on two PET scanners. We have modified the SimSET software to allow tracking singles in the object/collimator. For each single photon in the detector, the energy weighted average of interaction points is computed and a blurring model is applied to account for light-sharing. The detection crystal is then determined. Primary, scattered and random coincidences are binned in 3D sinograms while modeling the curvature effects. Energy spectra and single distributions predicted by this model in 2D and 3D modes were compared to GATE as well as two GE DST PET scanners for NEMA NU-2 2001 recommended tests. Very good agreement was found between GATE and our improved modeling of photon transport. Simulated spatial resolutions @ 1 cm and 10 cm agreed with measurements within the variations in measurements made on the two DST scanner (1 mm FWHM, 1 mm FWTM in every direction). Simulated scatter fractions were 18.7plusmn1.2% in 2D (measured: 20.6%) and 45.5plusmn5.5% (measured: 44.1%) in 3D. Mean error between simulated and measured sensitivity were 2.5% in 2D mode and 2.4% in 3D. The new model allows accurate and fast modeling of PET acquisition under realistic activity and attenuation distributions

Published in:

IEEE Nuclear Science Symposium Conference Record, 2005  (Volume:3 )

Date of Conference:

23-29 Oct. 2005