Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
S. C. Moore ; Dept. of Radiol., Brigham & Women's Hosp. & Harvard Med. Sch., Boston, MA, USA ; M. F. Kijewski ; G. E. Fakhri

We describe a new approach to the problem of collimator optimization in nuclear medicine; our methodology is illustrated for the challenging case of gallium-67 imaging. Collimator-design methods based on empirical rules, such as specification of an allowable level of single-septal penetration (SSP) at a fixed energy, are especially inappropriate for radionuclides characterized by an abundance of high-energy contaminant photons that scatter in the patient, collimator, and/or detector before detection within one of a few photopeak energy windows. Lead X-rays produced in the collimator are an additional source of contamination. We designed optimal collimation for 67Ga based on relevant clinical imaging tasks and a realistic simulation of photon transport in a phantom, collimator, and detector. Collimator designs were compared on the basis of performance in lesion detection, as predicted by a three-channel Hotelling observer (CHO), as well as in tumor and background activity estimation (EST), quantified by task-specific signal-to-noise ratios (SNRs). The optimal values of collimator lead content were 22.0 and 23.8 g/cm2, respectively, for CHO and EST, while the optimal geometric resolution values were 1.8 and 1.6 cm full-width at half-maximum (FWHM), respectively, at a distance of 23.5 cm. The resolution of a commercially available medium-energy low-penetration collimator (MELP) is 1.9 cm FWHM at this distance. The optimal values for SSP at 300 keV were 7.3% and 5.8% based on CHO and EST, respectively, compared to 5.2% for the MELP collimator. Compared with the commercial MELP collimator, the 67Ga collimator optimized for tumor detection or activity estimation tasks provided improved geometric spatial resolution with reduced geometric efficiency and, surprisingly, allowed an increased level of single-septal penetration.