Cart (Loading....) | Create Account
Close category search window
 

A busbar differential protection relay suitable for use with measurement type current transformers

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Yong-Cheol Kang ; Chonbuk Nat. Univ., South Korea ; Ui-Jai Lim ; Sang-Hee Kang ; Crossley, P.

Summary form only given. The design, evaluation and implementation of a busbar current differential protection relay suitable for use with measurement type current transformers (CTs) is described in the paper. The relay operates in conjunction with a saturation detection algorithm, which effectively detects the start and end of each saturation period using a technique based on the third-difference function applied to the current signal. A blocking signal is activated immediately after the onset of saturation and is maintained active until the saturation period plus an additional delay of one cycle has expired. For internal faults that result in CT saturation, the relay issues a trip command before the blocking signal is activated. For external faults, that result in CT saturation, the blocking signal arrives first and the trip command remains inactive. Test results indicate that the relay successfully discriminates between internal and external faults, even when the remanent flux in a CT is high and the fault capabilities of the measurement CTs are severely limited. The paper concludes by describing how the relay was implemented on a prototype relay based on a digital signal processor. Compared to a conventional busbar differential protection scheme, the new relay achieves greater stability on external faults and enhanced sensitivity for internal faults.

Published in:

Power Engineering Society General Meeting, 2005. IEEE

Date of Conference:

12-16 June 2005

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.