Guide wire reconstruction and visualization in 3DRA using monoplane fluoroscopic imaging

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Van Walsum, T. ; Univ. Med. Center Utrecht, Netherlands ; Baert, S.A.M. ; Niessen, W.J.

A method has been developed that, based on the guide wire position in monoplane fluoroscopic images, visualizes the approximate guide wire position in the three-dimensional (3-D) vasculature, that is obtained prior to the intervention with 3-D rotational X-ray angiography (3DRA). The method assumes the position of the guide wire in the fluoroscopic images is known. A two-dimensional feature image is determined from the 3DRA data. In this feature image, the guide wire position is determined in a two-step approach: a mincost algorithm is used to determine a suitable position for the guide wire, and subsequently a snake optimization technique is applied to move the guide wire to a better position. The resulting guide wire can then be visualized in 3-D in combination with the 3DRA dataset. The reconstruction accuracy of the method has been evaluated using a 3DRA image of a vascular phantom filled with contrast, and monoplane fluoroscopic images of the same phantom without contrast and with a guide wire inserted. The evaluation has been performed for different projection angles, and with different parameters for the method. The final result does not appear to be very sensitive to the parameters of the method. The average mean error of the estimated 3-D guide wire position is 1.5 mm, and the average tip distance is 2.3 mm. The effect of inaccurate C-arm geometry information is also investigated. Small errors in geometry information (up to 1°) will slightly decrease the 3-D reconstruction accuracies, with an error of at most 1 mm. The feasibility of this approach on clinical data is demonstrated.

Published in:

Medical Imaging, IEEE Transactions on  (Volume:24 ,  Issue: 5 )