Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and three-electrode biosensors

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

4 Author(s)
Beach, R.D. ; Univ. of Connecticut Health Center, Farmington, CT, USA ; Conlan, R.W. ; Godwin, M.C. ; Moussy, F.

A miniature implantable and dynamically configurable potentiostat and galvanostat for two- and three-electrode biosensors with a telemetry electronics package was developed to provide remote monitoring of implantable amperometric and voltametric biosensors such as for glucose. Included are circuitry for sensor biasing, a transimpedance amplifier to produce the sensor proportional output signal, and a transceiver (transmitter and receiver) which can both receive setup parameter values and transmit the biosensor concentration data to a corresponding remote transceiver and computer for monitoring. Remotely configurable features included in the in vivo implanted unit include: sensor excitation changes; filter frequency cutoff values, amplifier gain; and transmission intervals utilizing 303.825-MHz UHF RF telemetry for end-to-end remote data monitoring. The developed mP/Gstat printed circuit board measures about 51×22×1mm thick, and is suitable for bench top or encapsulated use. Instrumentation developed in this paper will allow other researchers to develop implantable units. Evaluation in two- and three-electrode mPstat and two electrode mGstat modes with simulated biosensors showed overall average theoretical to actual recorded value differences of only 0.5859% reading (RDG) with a standard deviation (SD) of 0.5376% indicating excellent design performance. System testing in two-electrode mPstat mode with actual glucose sensors showed excellent stability and correlation to standard biosensor calibrations with an average difference of only 7.33% full scale (FS) with 3.65% SD, which is minimal considering two totally independent calibration instrument configurations.

Published in:

Instrumentation and Measurement, IEEE Transactions on  (Volume:54 ,  Issue: 1 )