Precompensated excitation waveforms to suppress harmonic generation in MEMS electrostatic transducers

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Zhou, S. ; Dept. of Biomed. Eng., Virginia Univ., Charlottesville, VA, USA ; Reynolds, P. ; Hossack, J.

Microelectromechanical systems (MEMS) electrostatic-based transducers inherently produce harmonics as the electrostatic force generated in the transmit mode is approximately proportional to the square of the applied voltage signal. This characteristic precludes them from being effectively used for harmonic imaging (either with or without the addition of microbubble-based contrast agents). The harmonic signal that is nonlinearly generated by tissue (or contrast agent) cannot be distinguished from the inherent transmitted harmonic signal. We investigated two precompensation methods to cancel this inherent harmonic generation in electrostatic transducers. A combination of finite element analysis (FEA) and experimental results are presented. The first approach relies on a calculation, or measurement, of the transducer's linear transfer function, which is valid for small signal levels. Using this transfer function and a measurement of the undesired harmonic signal, a predistorted transmit signal was calculated to cancel the harmonic inherently generated by the transducer. Due to the lack of perfect linearity, the approach does not work completely in a single iteration. However, with subsequent iterations, the problem becomes more linear and converges toward a very satisfactory result (a 18.6 dB harmonic reduction was achieved in FEA simulations and a 20.7 dB reduction was measured in a prototype experiment). The second approach tested involves defining a desired function [including a direct current (DC) offset], then taking the square root of this function to determine the shape of the required input function. A 5.5 dB reduction of transmitted harmonic was obtained in both FEA simulation and experimental prototypes test.