13 Author(s)
Nakazawa, K. ; Inst. of Space & Astron. Sci., Kanagawa, Japan ; Oonuki, Kousuke ; Tanaka, T. ; Kobayashi, Y.
more authors

Recent results from the CdTe Schottky diode detectors employing a guard-ring electrode are reported. Cathode electrode, made of Pt, was separated into an active electrode(s) and a surrounding guard-ring. Typical leakage current of a device with an active area of 2 × 2 mm2 and 0.5 mm thickness surrounded by a guard-ring, is 7 pA and 20 pA at a bias of 100 V and 500 V, respectively, operated at 20 °C . Spectral resolution of this device is 0.93 keV and 1.2 keV (FWHM) at 59.5 keV and 122 keV, respectively, operated at 20 °C with a bias of 800 V. Detailed study of the characteristics of these devices working as a gamma-ray detector is presented.

Published in:

Nuclear Science Symposium Conference Record, 2003 IEEE  (Volume:5 )

Date of Conference:

19-25 Oct. 2003