By Topic

Development of image-based scatter correction for brain perfusion SPECT study: comparison with TEW method

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

7 Author(s)
Shidahara, M. ; Dept. of Biofunctional Res., Nat. Inst. for Longevity Sci., Obu, Japan ; Watabe, H. ; KyeongMin Kim ; Kawatsu, S.
more authors

In order to convert scatter uncorrected into corrected SPECT image, an image-based scatter correction (IBSC) method has been developed. The aim of this study was validation of its role as image converter from scatter uncorrected into corrected images equivalent to image corrected by conventional TEW method. IBSC method is executed in the postreconstruction process and only requires an attenuation corrected main photopeak image with broad μ value, IACμb. The scatter component image is estimated by convolving IACμb with a scatter function followed by multiplying with an image-based scatter fraction (SF) function. The IBSC method was evaluated with Monte Carlo simulations and 99mTc-ECD SPECT human brain perfusion studies obtained from five volunteers. The noise property of the scatter corrected image using IBSC method, IIBSC, was compared with that by TEW method, ITEW, with simulated brain phantom images. Image contrast between gray with white matter in the human study was also compared between IBSC and TEW method. The global signal-to-noise (S/N) ratio of IIBSC was decreased to 14% compared to that of IACμb, whereas that of ITEW was decreased to 21%. In human brain imaging, significant difference in image contrast between IBSC and TEW method was not observed (p<0.05). In conclusion, the IBSC method could be applied to clinical brain perfusion SPECT as conversion IACμb into a scatter corrected image equivalent to ITEW. This achieves a better noise property than the TEW method.

Published in:

Nuclear Science Symposium Conference Record, 2003 IEEE  (Volume:4 )

Date of Conference:

19-25 Oct. 2003