Feasibility of stereo-infrared tracking to monitor patient motion during cardiac SPECT imaging

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$33 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

9 Author(s)
R. D. Beach ; Div. of Nucl. Medicine, Univ. of Massachusetts Med. Sch., Worcester, MA, USA ; P. H. Pretorius ; Guido Boening ; P. P. Bruyant
more authors

Patient motion during cardiac SPECT imaging can cause diagnostic imaging artifacts. We investigated the feasibility of monitoring patient motion using the Polaris motion-tracking system. This system uses passive infrared reflection from small spheres to provide real-time position data with vendor stated 0.35 mm accuracy and 0.2 mm repeatability. In our configuration, the Polaris system views through the SPECT gantry toward the patient's head. List-mode event data were temporally synchronized with motion-tracking data utilizing a modified LabVIEW virtual instrument that we have employed in previous optical motion-tracking investigations. Calibration of SPECT to Polaris coordinates was achieved by determining the transformation matrix necessary to align the position of four reflecting spheres as seen by Polaris, with the location of Tc-99m activity placed inside the sphere mounts as determined in SPECT reconstructions. We have successfully tracked targets placed on volunteers in simulated imaging positions on the table of our SPECT system. We obtained excellent correlation (R2>0.998) between the change in location of the targets as measured by our SPECT system and the Polaris. We have also obtained excellent agreement between the recordings of the respiratory motion of four targets attached to an elastic band wrapped around the abdomen of volunteers and from a pneumatic bellows. We used the axial motion of point sources as determined by the Polaris to correct the motion in SPECT image acquisitions yielding virtually identical point source full-width at half-maximum and full-width at tenth-maximum values, and profiled maximum heart wall counts of cardiac phantom images, compared to the reconstructions with no motion.

Published in:

IEEE Transactions on Nuclear Science  (Volume:51 ,  Issue: 5 )