Detection of lumen-intima interface of posterior wall for measurement of elasticity of the human carotid artery

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Hasegawa, H. ; Graduate Sch. of Eng., Tohoku Univ., Sendai, Japan ; Kanai, H. ; Koiwa, Y.

In our series of studies on noninvasive assessment of the regional elasticity of the arterial wall, the displacement gradient (change in thickness) of the arterial wall caused by the heartbeat was measured by the phased tracking method. Because the displacement gradient corresponds to the strain due to the change in blood pressure, the elasticity can be evaluated from the displacement gradient of the arterial wall and the blood pressure, which are noninvasively measured at the upper arm. In the measurement of the elasticity of the arterial wall by our method, the region in which the elastic modulus is estimated must be assigned beforehand; currently, the lumen-intima boundary of the arterial wall is manually determined by the operator. For the real-time measurement of the elasticity of the arterial wall, a fast, automated method is necessary for detection of the boundary. In this paper, a cost function is proposed for differentiation of the arterial wall from the lumen. The proposed cost function was applied to ultrasound data, which were noninvasively obtained for five human carotid arteries. In comparison with the case of detection using only the amplitude of the echo, the root mean square error between the automatically detected lumen-intima boundary and the manually assigned boundary was significantly improved by using the proposed cost function. Furthermore, the lumen- intima boundary was automatically detected in a short period. Such a method is required for real-time measurement of the elasticity of the arterial wall, though detection of the outer boundary of the adventitia, which is not described in this paper, is also necessary to realize real-time elasticity measurement by our method.