Uzam, M. ; Muhendislik-Mimarlik Fak., Nigde Univ., Turkey ; Wonham, W.M.

In the above paper (A. Ghaffari et al., IEEE Trans. Automat. Contr., vol. 48, pp. 18-29, Jan. 2003) an example was given for which it was claimed that there exists no optimal Petri net-based (monitor) controller. It is stated that by using another method it is possible to obtain an optimal PN-based (monitor) controller.