6 Author(s)
Hughes, M.S. ; Cardiovascular Div., Washington Univ. Sch. of Med., St. Louis, MO, USA ; Marsh, J.N. ; Hall, C.S. ; Fuhrhop, R.W.
more authors

The ability to enhance specifically molecular markers of pathology with ultrasound has been previously demonstrated by our group employing a nanoparticle contrast agent. One of the advantages of this agent is it's relative non-echogenicity in the blood pool that allows increased contrast-to-noise between the blood pool and the bound, site-targeted agent. We sought to define the contrast agent concentration and acoustic parameters necessary to detect contrast enhancement in the blood so that molecular contrast enhancement could be more precisely defined. This study addresses two potential mechanisms that have been proposed for backscatter from the nanoparticle contrast agent in the blood pool - concentration-related scattering and phase conversion from liquid to gaseous perfluorocarbon. The nanoparticles were produced by methods currently standard in our laboratory using perfluorooctyl bromide (PFOB: b.p. 142°C) as the major component. Particle size was measured at 200±30nm. Attenuation coefficient and backscatter of the agent were measured in whole porcine blood (hct 40%) and porcine plasma maintained at 37°C. Specimens were insonified using a broadband, single element transducer (5 MHz, 2.54 cm diameter, 5.08 cm focal length). Acoustic pulses with usable bandwidth of 1.5 to 10 MHz, a repetition rate of 1kHz, and peak negative pressure of 3.9, 2.7, 1.5, and 0.8MPa (equivalent to M.I. of: 1.7, 1.2, 0.67, 0.36) were used to measure of attenuation coefficient and backscatter of nanoparticles at concentrations of 0.26, 0.51, 1.02, 2.04, 4.08×1014 particles/mL while suspended in either whole porcine blood or porcine plasma. The attenuation coefficient was linear at all concentrations and power levels and shows no evidence of a resonant peak characteristic of liquid-to-gas phase conversion. The back-scatter coefficient in plasma increased with concentration. However, in blood, backscatter was only significantly different from baseline at 2.04×l014 particles/mL and above (8x the maximum anticipated dose). These data indicate that phase conversion of PFOB to gas is not the source of the contrast in molecular imaging with site targeted nanoparticles.

Published in:

Ultrasonics, 2003 IEEE Symposium on  (Volume:1 )

Date of Conference:

5-8 Oct. 2003

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.