Cart (Loading....) | Create Account
Close category search window
 

Improvement of the depth of interaction detector for PET on full energy pulse height uniformity

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

10 Author(s)
Kasahara, T. ; Graduate Sch. of Sci. & Technol., Chiba Univ., Japan ; Murayama, H. ; Omura, T. ; Yamashita, T.
more authors

As part of the next generation PET project, uniformity of full energy pulse height for all crystal elements was improved in the depth of interaction (DOI) detector constructed of three-dimensional crystal arrays. In our previous report, we found that the DOI detector constructed of four stages of a 2 × 2 Gd2SiO5:Ce (GSO) crystal array provides good crystal identification performance but poor uniformity of the energy pulse height distribution. The upper stage crystal elements which stay further from the photocathode of a PMT have a tendency to show lower energy pulse height. For example, the ratio of the full energy peak of the top stage crystal to the bottom stage one was about 0.3. We designed a new DOI detector improved in the uniformity. By optimizing crystal surface finishes, reflector configurations, and optical coupling between crystal elements, we got comparable energy pulse height from the upper stage crystals to the bottom stage crystals. Despite this change of detector conditions, good separation between each area corresponding to crystal elements is maintained on two-dimensional histograms obtained by Anger-type position calculation. The uniform full energy pulse height of every stage crystal allows a narrower dynamic range of the electrical circuits, and may give a great advantage in getting an accurate scatter correction. It also improves energy and timing resolution.

Published in:

Nuclear Science, IEEE Transactions on  (Volume:50 ,  Issue: 5 )

Date of Publication:

Oct. 2003

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.