By Topic

Noninvasive imaging of cardiac transmembrane potentials within three-dimensional myocardium by means of a realistic geometry anisotropic heart model

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Bin He ; Univ. of Illinois, Chicago, IL, USA ; Guanglin Li ; Xin Zhang

We have developed a new approach for imaging cardiac transmembrane potentials (TMPs) within the three-dimensional (3-D) myocardium by means of an anisotropic heart model. The cardiac TMP distribution is estimated from body surface electrocardiograms by minimizing objective functions of the "measured" body surface potential maps (BSPMs) and the heart-model-generated BSPMs. Computer simulation studies have been conducted to evaluate the present 3-D TMP imaging approach using pacing protocols. Simulations of single-site pacing at 24 sites throughout the ventricles, as well as dual-site pacing at 12 pairs of sites in the vicinity of atrio-ventricular ring were performed. The present simulation results show that the correlation coefficient (CC) and relative error (RE) between the "true" and inversely estimated TMP distributions were 0.9915±0.0041 and 0.1266±0.0326, for single-site pacing, and 0.9889±0.0034 and 0.1473±0.0237 for dual-site pacing, respectively, when 10 μV Gaussian white noise (GWN) was added to the BSPMs. The effects of heart and torso geometry uncertainty were also evaluated by shifting the heart position by 10 mm and altering the torso size by 10%. The CC between the "true" and inversely estimated TMP distributions was above 0.97 when these geometry uncertainties were considered. The present simulation results demonstrate the feasibility of noninvasive estimation of TMP distribution throughout the ventricles from body surface electrocardiographic measurements, and suggest that the present method may become a useful alternative in noninvasive imaging of distributed cardiac electrophysiological processes within the 3-D myocardium.

Published in:

Biomedical Engineering, IEEE Transactions on  (Volume:50 ,  Issue: 10 )