Two distinctly different methods have been used to improve images produced in positron-emission tomography. The first method is to measure the differential time-of-flight of the photon pairs which are detected; the second is to use an iterative algorithm to compute maximum likelihood estimates of radioactivity distributions. The performances of algorithms which include neither, one or the other, or both methods of improvement have been quantified by performing a repetitive simulation experiment using the Hoffman brain phantom as the underlying distribution of radioactivity. Simulations show that all of the algorithms yield unbiased estimates of the desired image. The algorithm which computes maximum-likelihood estimates using time-of-flight information reconstructs images with the lowest variance. The algorithm which uses neither of these methods (filtered backprojection) reconstructs images with the highest variance
Published in:
Nuclear Science, IEEE Transactions on
(Volume:37
,
Issue:
2
)
Date of Publication: Apr 1990