Cart (Loading....) | Create Account
Close category search window
 

Calibration and performance of the UCR double Compton gamma ray telescope

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

8 Author(s)
Ait-Ouamer, F. ; Inst. of Geophys. & Planetary Phys., California Univ., Riverside, CA, USA ; Kerrick, A.D. ; Sarmouk, A. ; O'Neill, T.J.
more authors

Results of the field calibration and performance of the UCR double Compton gamma-ray telescope are presented. The telescope is a balloon-borne instrument with an upper array of 16 plastic scintillator bars and a lower one of 16 NaI(Tl) bars. The telescope is sensitive to celestial gamma rays from 1 to 30 MeV. The data were collected on Feb. 14, 1988 prior to the launch in Alice Springs, Australia to observe SN 1987A. Radioactive sources were used to calibrate the energy deposits in the scintillators. Each bar was analyzed laterally using pulse height or timing to obtain the positions of the gamma ray interactions. Double scatter events from a 24Na source simulating a celestial source were studied to obtain the general performance of the telescope and to develop imaging techniques, later used with the flight data. An angular resolution of 11° FWHM (full width at half maximum) and energy resolutions of 13% FWHM at 1.37 MeV and 10% FWHM at 2.75 MeV were found. The efficiency of the telescope is 3.5×10-3 at an energy of 1.37 MeV and zenith angle of 31°. The magnetometer calibration gives the orientation of the detector with respect to the Earth to an accuracy of 0.5°

Published in:

Nuclear Science, IEEE Transactions on  (Volume:37 ,  Issue: 2 )

Date of Publication:

Apr 1990

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.