Cart (Loading....) | Create Account
Close category search window
 

Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

2 Author(s)
Segars, W.P. ; Dept. of Biomed. Eng., North Carolina Univ., Chapel Hill, NC, USA ; Tsui, B.M.W.

Respiratory motion can cause artifacts in myocardial single photon emission computed tomography (SPECT) images, which can lead to the misdiagnosis of cardiac diseases. One method to correct for respiratory artifacts is through respiratory gating. We study the effectiveness of respiratory gating through a simulation study using the newly developed four-dimensional (4-D) NURBS-based cardiac-torso (NCAT) phantom. The organ shapes in the 4-D NCAT phantom are formed using nonuniform rational b-splines (NURBS) and are based on detailed human image data. With its basis on actual human data, the 4-D NCAT phantom realistically simulates human anatomy and motions such as the cardiac and respiratory motions. With the 4-D NCAT phantom, we generated 128 phantoms over one respiratory cycle (5 s per cycle) with the diaphragm and heart set to move a total of 4 cm from end-inspiration to end-expiration. The heart was set to beat with a normal contractile motion at a rate of I beat per second resulting in a total of five heart cycles. We divide the respiratory cycle into different numbers of respiratory gates (16, 8, and 4) by summing the phantoms. For each gate, we generate its projection data using an analytical projection algorithm simulating the effects of attenuation, scatter, and detector response. We then reconstruct the projections using an iterative OS-EM algorithm compensating for the three effects. The reconstructed images for each gating method were examined for artifacts due to the respiratory motion during that gate. We found that respiratory artifacts are significantly reduced if the respiratory motion of the heart that occurs during a gating time period is 1 cm or less. We conclude that respiratory gating is an effective method for reducing effects due to respiration. The timing of the respiratory gates for reduced image artifacts is dependent on the extent of the heart's motion during respiration. Index Terms-Biomedical image processing, biomedical nuclear imaging, image analysis, motion compensation, respiratory system, simulation software, single photon emission computed tomography (SPECT).

Published in:

Nuclear Science, IEEE Transactions on  (Volume:49 ,  Issue: 3 )

Date of Publication:

Jun 2002

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.