Cart (Loading....) | Create Account
Close category search window
 

Calibration of a calorimeter for measuring the spark energy of an electrostatic discharge

Sign In

Cookies must be enabled to login.After enabling cookies , please use refresh or reload or ctrl+f5 on the browser for the login options.

Formats Non-Member Member
$31 $13
Learn how you can qualify for the best price for this item!
Become an IEEE Member or Subscribe to
IEEE Xplore for exclusive pricing!
close button

puzzle piece

IEEE membership options for an individual and IEEE Xplore subscriptions for an organization offer the most affordable access to essential journal articles, conference papers, standards, eBooks, and eLearning courses.

Learn more about:

IEEE membership

IEEE Xplore subscriptions

3 Author(s)
Kucerovsky, Z. ; Dept. of Electr. & Comput. Eng., Univ. of Western Ontario, London, Ont., Canada ; Greason, W.D. ; Flatley, M.W.

This paper deals with the factors that influence the accuracy of the measurements performed with a calorimeter, developed to detect the optical signal emitted by the spark generated to facilitate experiments with electrostatic discharge. Experiments are described which were performed with a special calorimeter and a compound optical source consisting of a spark gap, a human-body-model electrostatic discharge (ESD) signal generator, and four LEDs. The spark gap was used as a versatile and more powerful source of optical emission than the human-body-model circuit; the LED source was used for calibration and alignment. For control, the spectrum of the spark discharge was measured with a spectrometer and a broadband photodetector. The calorimeter was used as a means for the determination of the energy contained in the optical signal, yielding the value of the spark-gap emission in the fundamental units for energy. The long-term stability of the system was measured, and the system response was studied for threshold optical signals. The calorimeter detectivity, defined as the overall instrument sensitivity, measured in volts per joule, was D=4.3×107 V.J-1 and its detection limit 2.3×10-13 J. The system's response to the IEC standard human-body-model circuit was consistent with the measurements of the system's detectivity. Most parts of the developed apparatus have been tested in an industrial environment.

Published in:

Industry Applications, IEEE Transactions on  (Volume:38 ,  Issue: 5 )

Date of Publication:

Sep/Oct 2002

Need Help?


IEEE Advancing Technology for Humanity About IEEE Xplore | Contact | Help | Terms of Use | Nondiscrimination Policy | Site Map | Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest professional association for the advancement of technology.
© Copyright 2014 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.